                    Post Encoding:211600

                    The electronic computer shielded cable

                    電子計(ji)算(suan)機(ji)屏(ping)蔽(bi)電纜(lan).jpg
                    • 電(dian)子(zi)計(ji)算機(ji)屏(ping)蔽(bi)電纜(lan).jpg
                    Electronic computer shielded cable is used for power generation, metallurgy, petrochemical and other…

                    Description:

                    A, product characteristics and USES:
                    Electronic computer shielded cable is used for power generation, metallurgy, petrochemical and other industrial and mining enterprises and distributing system, computer system, signal transmission of the automation system and testing instruments, meters and other connection with multiple of shielded cable.
                    Second, the electronic computer shielded cable using features:
                    Working temperature: general type does not exceed 70 ℃, after the model 105 is highest do not exceed 105 ℃.
                    Minimum ambient temperature: fixed installation to 40 ℃ the fixed installation to 15 ℃
                    The rated voltage Uo/U: 300/500 v
                    The minimum bending radius: no armoured layer cable should be not less than 6 times of cable diameter
                    Layer with armored cable should be not less than 12 times of cable diameter
                    Three, computer shielded cable main technical indicators:

                    Performance of the projectunitTechnical indicators
                    Polyethylene insulationPVC insulated
                    Insulation resistance when 20 ℃As a line between the conductorsM Ω · km50025
                    Between the shielding line11
                    Capacitance (1 KHZ)Type 3pF/m75200
                    1 and 290
                    Capacitance unbalance (1 KHZ)pF/M1/
                    Inductive resistance thanCross sectionMu h/Ω20
                    20
                    25
                    35
                    20
                    20
                    25
                    35

                    0.5mm2
                    0.75mm2
                    1.0mm2
                    1.5mm2






                    Shielding inhibition coefficient or less
                    0.010.01
                    Test voltageV/1min10001000
                    Flame retardant
                    Comply with the requirements of 12666-90Comply with the requirements of 12666-90

                    Four, computer shielded cable type:


                    projectCode nameinstructions
                    Flame retardant code/
                    ZR
                    ZRA
                    ZRB
                    ZRC
                    The flame retardant can be omitted
                    Flame retardant
                    Grade A flame retardant
                    Class B fire retardant
                    Class C fire retardant
                    A series of codesDJThe electronic computer (including DCS system) and electric instrument
                    Insulation materialsY
                    V
                    D
                    W
                    polyethylene
                    Polyvinyl chloride (PVC)
                    Low smoke low halogen polyvinyl chloride (PVC)
                    Low smoke zero halogen polyvinyl chloride olefins
                    Shielding materialsP
                    P1
                    P2
                    P3
                    Copper wire braided
                    Tin plated copper wire weaving
                    Copper/polyester composite membrane
                    Aluminum/polyester composite membrane
                    Sheath materialY
                    V
                    D
                    W
                    Heat resistant polyethylene
                    Polyvinyl chloride (PVC)
                    Low smoke low halogen polyethylene
                    Low smoke zero halogen polyolefin
                    Armoring materials22Steel tape armoured
                    Conductor typeA
                    B
                    R
                    Single strand conductors
                    Seven strands of stranded conductor
                    More flexible conductor
                    specifications
                    Fill in the logarithmic x (unit some x conductor cross section)
                    Logarithmic N: 1, 2, 3,......19
                    Unit some n: 2, 3
                    S: conductor section 0.5, 0.75, 1.0, 1.5, was