                    Far eastone gas turbine flowmeter

                    6氣(qi)體渦(wo)輪(lun)流(liu)量(liang)計(ji)(遠傳(chuan)).jpg
                    • 6氣(qi)體(ti)渦輪(lun)流(liu)量計(遠傳).jpg
                    ZW - LWQ seriesFar eastone gas turbine flowmeterItself does not have the scene display, only the tra…

                    Description:

                    ZW - LWQ seriesFar eastone gas turbine flowmeterItself does not have the scene display, only the transmission of traffic signal far out.Traffic signals can be divided into the pulse signal or 4-20 ma current signal, low price, high integration, small size, especially suitable for display instrument and instrument for computer control system, PLC, DCS, etc.This kind of turbine flowmeter are explosion-proof products, explosion-proof grade for ExdIIBT6.Equipped with health joint turbine flow sensor can be used in the pharmaceutical industry, far eastone turbine can also be connected to the control room of the secondary instrument, integrating, transport, communication and control functions.

                    Second, the working principle:
                    ZW - LWQ seriesFar eastone working principle of gas turbine flowmeter is a fluid flowing through the sensor shell, as a result of the impeller blade and flow to a certain point of view, the impact of fluid blade with rotational torque, to overcome the friction torque and fluid resistance, blade rotation speed stability after the moment balance, under certain conditions, the speed is proportional to the velocity of flow, because there are magnetic conductivity blade, it is in the signal detector (composed of * magnetic steel and coil) magnetic field, rotating blade cutting lines, periodically changing coil magnetic flux, so that the coil ends induction electrical pulse signal, the signal after amplifier amplification plastic, form a certain amplitude of continuous rectangular pulse wave, can be spread far to display instrument, show the instantaneous flow and cumulative amount of fluid.Within the scope of a certain flow, pulse frequency f and flows through the sensor of fluid is proportional to the instantaneous flow rate Q, flow equation is: Q = 3600 x f/k;Type:
                    F - pulse frequency (Hz);
                    K - the instrument coefficient of sensor 1 / m3, given by the check list.If [1 / L] as the unit
                    Q - fluid transient flow (working conditions) (m3 / h),
                    3600 - conversion factor.
                    Coefficient of each sensor of the instrument in the calibration certificate will be completed by the manufacturer, set into the display instrument of form a complete set of k value, can show the instantaneous flow and cumulative total.
                    Applications:
                    ZW - LWQ seriesFar eastone gas turbine flowmeter is learned the flow meter at home and abroad advanced technology optimized design, integrated the theory of gas mechanics, fluid mechanics, electromagnetism and developed a new generation of high precision, high reliability of gas precision measuring instrument, has a good performance of low pressure and high pressure measurement, multiple way signal output and low sensitivity to the fluid disturbance, is widely used in natural gas, coal gas, liquefied gas and light hydrocarbon gas and gas metering.
                    Four, the main features:
                    1, sensor is cemented carbide bearing thrust type, not only guarantee the accuracy, and improve the wear resistance.
                    2, simple structure, strong and tear open outfit is convenient.
                    3, wide measuring range, low threshold velocity.
                    4, small pressure loss, good repeatability, high precision.
                    5, have a high resistance to electromagnetic interference and vibration resistance.
                    Five, the technical parameters:
                    Meter diameter: threaded connections: 4, 6, 10, 15, 20, 25, 32, 40;
                    Flange connection: (15, 20, 25, 32, 40, 50, 65, 80, 100, 125, 150, 200;
                    Insert: more than 200;
                    Range scale: 1:10;1:15.1;
                    Instrument material: stainless steel 304, 316 (L) stainless steel, etc;
                    Medium temperature: - 20 ℃ ~ + 120 ℃;
                    Ambient temperature: - 10 ℃ ~ + 55 ℃;
                    Relative humidity: 5% ~ 9%;
                    The atmospheric pressure: 86 ~ 106 kpa;
                    Power supply: the scene display type: instrument with lithium batteries;
                    Explosion-proof forms: basic not explosion-proof, explosion-proof type;
                    Protection grade: IP65, IP67.
                    Six, instrument type:
                    A, the scene display type:
                    The intelligent flowmeter is the use of advanced single chip microcomputer technology design of the new display instrument of the flow meter, and the flow sensor of pulse signal output (such as turbine, vortex.).It can display instantaneous flow and cumulative amount.Cumulative flow: eight digit, decimal point three significant figures.Instantaneous flow: six figures, but showed a litre.Display precision: plus or minus a display unit.Signal output: pulse output: 1 ~ 3000 hz for + 12 ~ + 24 VDC power supply output current: 4 ~ 20 ma away for + 24 VDC power supply (two wire system) built-in 2 section 3 v lithium battery power supply in parallel.When the voltage is lower than 2.7 V, the under-voltage directives flameproof.Small signal removal function.
                    B, pulse output type:
                    Working voltage: + + 12 VDC or 24 VDC two (customer order must be selected before a power supply).Signal transmission distance: less than 250 meters.Output signal, square wave signal amplitude: + 12 VDC power supply amplitude is about 10 v + 24 VDC power supply amplitude of about 20 v: amplifier and turbine flow sensor connection for the M16 x 1.5 thread, after the turbine flow sensor installation, twist to the turbine flow sensor, the amplifier with the hand twist to sense amplifier and then take the lock nut.Connection: type pulse output amplifier foreign lead with three root, red, white line and shielding.Is the power supply line, white line for pulse output and display, or other equipment connection, shielding grounding
                    C, 4 ~ 20 ma output type:
                    Outside the working voltage: 24 VDC power supply + (two wire system) output signal: 4 ~ 20 ma, or 1, 4-5 v ma corresponding to zero flow turbine flow sensor, 20 ma for turbine flow sensor zui large flow, flow range turbine flow sensor nameplate.Signal transmission distance: less than 250 meters.After the installation of turbine flow sensor installation, twist the amplifier to the turbine flow sensor (m16 x 1.5 thread), joint hands after twist to the sense amplifier has exactly bring tight lock nut.Connection: 4 ~ 20 ma output type amplifier foreign fuses with the red and white line.The red line for the power cord, white line for line.
                    D, fission remote display type:
                    Outside power supply working voltage: 220 vac signal transmission distance: less than 250 meters display instantaneous four: accumulative total nine display display size: horizontal type: 160 mm x 80 mm upright: 80 mm x 160 mm display with 4 ~ 20 ma output and can be connected to the computer.
                    Seven, structure and installation method:
                    1, instrument installation using thread connection and clamp type;
                    2, liquid flow direction when installation should be direction of arrow and indicating flow sensor shell, and a straight pipe upstream should be 6 D, or downstream straight pipe should be 5 D or higher measured pipeline measured diameter (D).
                    3, sensors should be far away from the external magnetic field, such as can't be avoided, necessary measures should be taken;
                    4, in order to not affect the normal delivery of the liquid, maintenance should be straight section on opposite sides of the sensor installation outside the by-pass pipe;
                    5, sensors, outdoor installation time, please prepare amplifier plug waterproof processing;
                    6, sensor and display instrument connection, should according to the power of the amplifier to choose connection mode, as shown in the relevant specification.
                    Eight, wiring and grounding considerations:
                    Wiring matters needing attention
                    1, using a full cable as soon as possible.
                    2, should as far as possible away from electrical noise (such as power transformer, electric motor and the power cord), avoid parallel to the power the power cord wiring.
                    3, Suggestions in the end of the thick wire adopts the tin welding clamping lugs.
                    4, for the waterproof and mechanical damage, the cable into the metal tube inside, but may not have high power transmission cables, within the same catheter (a transmission cable transmission of zui power is greater than the flowmeter signal transmission cables zui small power 10 times, both cannot be installed on the same catheter).
                    5, the existing strong magnetic field outside the area, should make the axis of the detection device with the outside world vertical or the direction of the magnetic flux of the magnetic field with high permeability material for shielding flow sensor or external magnetic source.
                    6, explosion-proof type turbine flow sensor cable connection, must strictly abide by the relevant standards of explosion-proof amplifier.
                    Grounding problem
                    1, the shielding wire can only be grounded at one end, on display instrument grounding.
                    2, reliable grounding should be good, explosion-proof type grounding resistance should be less than 10 Ω.
                    The use of turbine flow time must pay attention to the points:
                    1, requires clean measured medium, low viscosity, corrosion resistance is small, do not contain impurities, in order to reduce the wear of bearing.If the liquid to be measured a grudge or containing gas, the flowmeter before venting device.In order to avoid damage of impurity in the fluid into the transmitter devious, and in order to prevent turbine stuck, add filters when necessary.
                    2, the installation of the flowmeter should avoid vibration, avoid magnetic field and thermal radiation.
                    3, medium density and viscosity changes have an impact on flow value, should be revised if necessary.
                    Nine, use requirements:
                    Measured liquid 1, when using, should maintain clean, do not contain impurities such as fiber and particles.
                    2, sensors, at the beginning of the use should be to slowly filled with liquid sensor, and then open the outlet valve (the valve should be installed in the back-end flow meters), it is strictly prohibited to sensors in liquid state under high velocity impact.
                    The maintenance period of 3, sensors, generally for half a year.Maintenance when cleaning, please note that you are the measuring chamber of damaged parts, especially in the impeller.Please watch the orientation and the position of the impeller when assembling.
                    4, sensors, need not when, should be clean inside the liquid, dry and after on both ends of the sensor and protective cover, prevent dirt to enter, and then placed in a dry place preservation.(this is very important)
                    5, with the filter should be cleaned regularly, need not when should clean the internal liquid, like sensors, dustproof set, placed in a dry place preservation.
                    6 transmission cables, the sensor can be raised or buried (buried iron pipe should be set.
                    7, in front of the sensor installation, and the first display instrument or oscilloscope connected wires, power supply, with my mouth to blow or hand dial the impeller, make its rapid rotation observations have showed that sensor installation again when have shown.If no display, should check the relevant parts, troubleshooting.

                    Ten, installation site:
                    1, the installation site should comply with the environmental temperature at 25 ~ 55 ℃ scope, humidity < 80% RH;
                    2, well ventilated, avoid sun and rain;
                    3, avoid in piping vibration or the place of stress;
                    4, avoid easily affected by the strong thermal radiation and radioactive places;
                    5, must avoid the outside strong electromagnetic field disturbance to the detection signal.If unavoidable, should be set on the amplifier of the flowmeter (sensor) shield and other measures to eliminate interference;
                    6, in the places where requires explosion-proof, and isolation amplifier should be adopted;
                    7, the installation position should consider ease of installation, operation, maintenance.

                    11, using a note:

                    1, in the low pressure table z pressure leak detection: 1.0 Mpa, or less temperature pressure compensation type leakage pressure no more than three times the upper limit value of the pressure sensor.High pressure casing according to 1.2 times the rated flow pressure leak detection.

                    2, after installation leak test and installation shall comply with the following provisions:

                    A close vent valve and the inlet valve first.

                    B slightly open vent valve, and then slowly open the inlet valve, make the table start slowly, then slowly open the vent valve, make the reach normal operation state, to prevent sudden start, damage to the core.

                    C at the time of stopping air, need to close the vent valve, then close the inlet valve, each time you start all should abide by the rules.

                    After 3, install and use, not to touch the bolt, screw, nut fasteners, such as to avoid danger such as leakage, damage.

                    4, flow meter movement (temperament clean) should be once every six months for cleaning maintenance;(temperament is dirtier) should be cleaning maintenance once a month.

                    5, if the movement after breakdown maintenance, to be put into use, the need to press z pressure seal test first.And note within the movement precision instrument transformer oil or oil.

                    Twelve, parameter table:

                    Instrument model

                    ZW-LWQ-N

                    ZW-LWQ-A

                    ZW-LWQ-B

                    ZW-LWQ-C

                    ZW-LWQ-D

                    Signal output

                    pulse

                    4-20mA

                    There is no

                    4-20mA

                    Optional 4-20 ma/pulse

                    Power supply

                    +24VDC±15%

                    +24VDC±15%

                    The lithium battery

                    24VDC±15%

                    24 VDC plus or minus 15% + lithium battery

                    Precision grade

                    2.5 ~ 1.5 on the Richter scale are unlikely

                    1.5 ~ 1.0 on the Richter scale are unlikely

                    1.5 ~ 1.0 on the Richter scale are unlikely

                    Measuring range

                    The standard range

                    Standard range or extension

                    Standard range or extension

                    display

                    There is no

                    There are

                    There are

                    Temperature, pressure compensation

                    There is no

                    There is no

                    There are

                    Communication interface

                    There is no

                    There is no

                    RS485

                    Real time record

                    There is no

                    There is no

                    There are

                    Instrument material

                    Aluminum alloy or stainless steel

                    Aluminum alloy or stainless steel

                    Aluminum alloy or stainless steel

                    Explosion-proof grade

                    ExdIIBT6 or ExiaIICT4

                    ExdIIBT6 or ExiaIICT4

                    ExdIIBT6 or ExiaIICT4

                    Protection grade

                    IP65

                    IP65

                    IP65

                    The machine power consumption

                    < 1W

                    < 1W

                    < 1W

                    Instrument drift diameter

                    DN25~DN300

                    DN25~DN300

                    DN25~DN300

                    installation

                    Flange installation

                    Flange installation

                    Flange installation

                    Medium temperature

                    - 20 ℃ ~ 80 ℃

                    - 20 ℃ ~ 80 ℃

                    - 20 ℃ ~ 80 ℃

                    The environment temperature

                    - 30 ℃ ~ 60 ℃

                    - 30 ℃ ~ 60 ℃

                    - 30 ℃ ~ 60 ℃

                    13, measurement range and pressure rating:

                    Nominal diameter
                    (mm)

                    model

                    The standard range
                    (m³/h)

                    Extended range
                    (m³/h)

                    Stress levels
                    (Mpa)

                    High pressure rating
                    (Mpa)

                    installation

                    DN20

                    ZW-LWQ-20

                    2.2-25

                    4-40

                    1.6

                    2.5, 4.0

                    The flange

                    DN25

                    ZW-LWQ-25

                    2.2-25

                    4-40

                    1.6

                    2.5, 4.0

                    Flange (thread)

                    DN32

                    ZW-LWQ-32

                    5-50

                    6-60

                    1.6

                    2.5, 4.0

                    The flange

                    DN40

                    ZW-LWQ-40

                    5-50

                    6-60

                    1.6

                    2.5, 4.0

                    Flange (thread)

                    DN50

                    ZW-LWQ-50

                    6-65

                    5-70.

                    1.6

                    2.5, 4.0

                    The flange

                    ZW-LWQ-50

                    10-100.

                    8-100.

                    DN65

                    ZW-LWQ-65

                    15-200.

                    10-200.

                    1.6

                    2.5, 4.0

                    The flange

                    DN80

                    ZW-LWQ-80

                    13-250.

                    10-160.

                    1.6

                    2.5, 4.0

                    The flange

                    ZW-LWQ-80

                    20-400.

                    The flange

                    DN100

                    ZW-LWQ-100

                    20-400.

                    13-250.

                    1.6

                    2.5

                    The flange

                    ZW-LWQ-100

                    32-650.

                    The flange

                    DN125

                    ZW-LWQ-125

                    25-700.

                    20-800.

                    1.6

                    2.5

                    The flange

                    DN150

                    ZW-LWQ-150

                    32-650.

                    80-1600.

                    1.6

                    2.5

                    The flange

                    ZW-LWQ-150

                    50-1000.

                    The flange

                    DN200

                    ZW-LWQ-200

                    80-1600.

                    50-1000.

                    1.6

                    ...

                    The flange

                    ZW-LWQ-200

                    130-2500.

                    The flange

                    DN250

                    ZW-LWQ-250

                    130-2500.

                    80-1600.

                    1.6

                    ...

                    The flange

                    ZW-LWQ-250

                    200-4000.

                    The flange

                    DN300

                    ZW-LWQ-300

                    200-4000.

                    130-2500.

                    1.6

                    ...

                    The flange

                    320-6500.

                    1.6

                    14, selection of coding:

                    type

                    ZW□□□

                    -

                    -

                    -

                    -

                    Instructions (in the wei and control)

                    LWQ-N





                    Basic three-wire system output pulse signal,+24VThe power supply

                    LWQ-A





                    Current output type4~20mAThe output,+24VThe power supply

                    LWQ-B





                    The display type3.6VBattery power

                    LWQ-C





                    The scene shows with4~20mAOr pulse output;+24VThe power supply

                    LWQ-D





                    Flow transmitter4~20mAThe output,+24VThe power supply.Temperature pressure compensation type

                    Nominal diameter

                    20




                    The normal flow

                    The scope ofm3/h

                    2.5-25 m3/h

                    Expand the flow

                    The scope ofm3/h

                    4-40 m3/h

                    25




                    2.5-25 m3/h

                    4-40 m3/h

                    32




                    5-50 m3/h

                    6-60 m3/h

                    40




                    5-50 m3/h

                    6-60 m3/h

                    50




                    6-65 m3/h

                    5-70 m3/h

                    65




                    15-200m3/h

                    10-200m3/h

                    80




                    13-250 m3/h

                    10-160 m3/h

                    100




                    20-400 m3/h

                    13-250 m3/h

                    125




                    25-700m3/h

                    20-800 m3/h

                    150




                    32-650 m3/h

                    50-1000 m3/h

                    200




                    80-1600 m3/h

                    800-1600 m3/h

                    250




                    130-2500 m3/h

                    80-1600 m3/h

                    300




                    200-4000 m3/h

                    320-6500 m3/h

                    explosion-proof




                    No mark for the explosion proof type

                    B



                    Explosion-proof type

                    Precision grade

                    A


                    precision1.0level

                    B


                    precision1.5level

                    C


                    precision2.5level

                    The turbine type

                    A

                    Normal flow range

                    B

                    Expand the flow range

                    For example, the model is:ZW-LWQA50BA-AThe gas turbine flowmeter, said:
                    Meter diameter for50mm, display and output way of live shows, the output current for measuring precision1.0%;Turbine types are measured normal flow range of remote transmission type gas turbine flowmeter.

                    15 and designing order selection guidelines:

                    1, instrument selection, as far as possible not to use the work flow in the lower limit value, so the meter diameter should be as small as possible, in order to obtain a larger flow rate and flow range.

                    2, the flowmeter should be used in the technical parameters of medium pressure and temperature range.Don't deliberately choose the high pressure level and ultra-high temperature instrument, should be selected according to the actual work pressure and temperature instruments, which had higher prices.

                    3, in the explosive dangerous location, should choose explosion-proof type flowmeter.

                    4, the lower limit of flowmeter flow depends on the operation condition of the medium density and kinematic viscosity, the maximum flow is generally not affected by medium pressure and temperature, so to determine the flow range as long as you determine the actual minimum flow can be available.Calculate the minimum flow rate, flow range check table to determine the appropriate diameter.

                    After-sales service commitment:

                    1, from the date of signing of the contract, I in the way provided for products of the company offers free maintenance and maintenance service, commitment to lifelong maintenance service;

                    2, jiangsu wei measurement and control instrument co., LTD. Sales manager will be in regular contact with customers, understand the usage of products, and solve the problems of the customers to use in the process of produce, free of charge to provide technical support;

                    3 the man-made damage is found, the warranty period, our company is responsible for the maintenance, and the resulting maintenance fee;

                    4, product quality problems or are not satisfied with product, the user can choose unconditional return, wei tt&c don't charge any fees, appear quality problem, bear the freight back and forth.