                    Hello! Welcome to Jiangsu Zhongwei Measurement and Control Instrument Co., Ltd.
                    0517-86918678
                    Address:No. 4-4 East West Road, Jinhu County Industrial Concentration Zone, Huaian City, Jiangsu Province
                    Tel:0517-86918678
                    Fax:0517-86918679
                    Email:zhongweick@https://gzdeyoo2018.com
                    Post Encoding:211600

                    Bearing load detection cable

                    承荷探(tan)測(ce)電(dian)纜.jpg
                    • 承荷探(tan)測電(dian)纜(lan).jpg
                    Bearing load detection cable is suitable for electrical measurements of mechanical load under oil de…

                    Description:

                    One, the cable's brief introduction:
                    Bearing load detection cable is suitable for electrical measurements of mechanical load under oil detection cable, this type of cable is used for all kinds of oil and gas well logging, perforation and coring operation;Can also be used in ocean, river, harbor, water conservancy, hydrographic survey, coalfield geological prospecting, geothermal well logging, etc.As weighing measuring instrument connections.
                    Second, the production standards
                    JB3302-1999 
                    Three, bearing load detection cable model name:

                    model
                    The name says
                    W7X
                    7 core natural styrene-butadiene rubber insulation double steel wire armoured bearing load detection cable
                    W7F46
                    7 core fep insulated double steel wire armoured bearing load detection cable
                    W7F46P
                    7 core fep insulated total shielding double steel wire armoured bearing load detection cable
                    W7F46PP
                    7 core fep insulated split-phase total shield the double steel wire armoured bearing load detection cable

                    Three, bearing load cable detection use performance:
                    1) cable allows the use of temperature range

                    Type no.
                    Using temperature range (℃)

                    No less than

                    Short-term stay for no more than 2 hours (a) above

                    W7X
                    - 40
                    90
                    W7F46
                    - 50
                    232
                    W7F46P
                    - 50
                    232
                    W7F46PP
                    - 50
                    232

                    (2) the winch drum diameter should not less than 400 mm, wellhead pulley, day pulley, the pulley of the bending radius should not less than 230 mm, pulley groove should be in line with the cable diameter
                    (3) the some of the cable length, cross section, tensile force, nominal rating manufacturing

                    Type no.
                    core
                    The number
                    Calculate the cross section
                    (mm2)
                    Nominal tensile
                    Power (KN)
                    Nominal manufacturing length (m)
                    W7X
                    7
                    0.56
                    44
                    -
                    -
                    -
                    -
                    -
                    3500
                    2200
                    W7F46
                    7
                    0.56
                    69
                    8000
                    7500
                    6500
                    5500
                    4200
                    3500
                    2200
                    W7F46P
                    7
                    0.56
                    69
                    8000
                    7500
                    6500
                    5500
                    4200
                    3500
                    2200
                    W7F46PP
                    7
                    0.56
                    69
                    8000
                    7500
                    6500
                    5500
                    4200
                    3500
                    2200

                    (4) the cable core dc resistance is not less than 36 Ω/km;Line between core, line between the core and armoured withstand ac 50 hz, 1000 v not breakdown voltage test for 1 minute